Vertical autoclaves for your laboratory

Vertical autoclaves with a chamber volume of 80-150 liters
The Laboratory- Vertical- Standing- Autoclaves, short LVSA, are characterized by their low loading height and easy operation.
Our autoclaves are available in four different sizes:
Dimensions:
Model | LVSA 40/60 | LVSA 40/75 | LVSA 50/60 | LVSA 50/70 |
---|---|---|---|---|
Effective space in mm | (Ø)400 x (H)625 | (Ø)400 x (H)775 | (Ø)500x (H)655 | (Ø)500x (H)755 |
Chamber volume in liters | 80 | 96 | 133 | 153 |
Loading height (mm) | 760 | 900 | 800 | 900 |
External diameter in mm | (W) 550 x (D) 850 | (W) 750 x (D) 950 | ||
Heating capacity (kW) | 6 | 9 | ||
Electrical connection | 380 – 400V, 50/60 Hz, 16 A |
The following equipment variants are available:
Basic LabRecommendedfor the sterilization of simple materials or liquids without removal dry. | Integrated steam generatorSteriTouch control |
Dry LabRecommendedfor the sterilization of non-infectious waste bags and materials which require intensive subsequent drying. | Integrated steam generatorVacuum pump setSteriTouch control |
Quick Lab Basic Recommended for the sterilization of large quantities of liquids. | Integrated steam generatorRapid water recooling system with air-circulating fanSteriTouch control |
Quick LabRecommendedfor the sterilization of non-infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying. | Integrated steam generatorVacuum pump setRapid water recooling system with air-circulating fanSteriTouch control |
Quick Lab AdvancedRecommendedfor the sterilization of non-infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying – this also applies to liquids in closed containers. | Integrated steam generatorVacuum pump setRapid water recooling system with air-circulating fanSteam/air mixture method (SAMM)SteriTouch control |
Safe LabRecommendedfor operation in the level S2 lab. Recommended for the sterilization of infectious waste bags and materials which require intensive subsequent drying. | Integrated steam generatorVacuum pump setExhaust air filtration EAFSteriTouch control |
Complete LabFullyequipped laboratory autoclave for operation in the level S2 lab. Recommended for the sterilization of infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying. | Integrated steam generatorVacuum pump setExhaust air filtration EAFRapid waterrecooling system with air-circulating fanSteriTouch control |

Zirbus vertical autoclave LVSA 50/60
Loading capacity
(Specifications partly only possible without loading baskets!)
Medium bottles (Schott) | LVSA 40/60 | LVSA 40/75 | LVSA 50/60 | LVSA 50/70 |
---|---|---|---|---|
500ml | 2×13 | 3×13 | 2×23 | 3×23 |
1000ml | 2×9 | 3×9 | 2×16 | 3×16 |
Erlenmeyer flasks | LVSA 40/60 | LVSA 40/75 | LVSA 50/60 | LVSA 50/70 |
---|---|---|---|---|
500ml | 2×8 | 3×8 | 2×15 | 3×15 |
1000ml | 2×5 | 3×5 | 2×9 | 3×9 |

Description of the individual components
Steam generator-integrated in the housing of the autoclave. Ensures rapid heating and cooling compared to conventional heating systems.
Vacuum pump set-for mechanical removal of air and drying in vacuum. Possible methods include single-stage vacuum, fractionated vacuum, constant or pulsating drying under a vacuum.
Lifting and pivoting mechanism – makes loading and unloading of vertically loaded autoclaves easier. The load capacity is 30 kg.
Exhaust air filtration-is stipulated for the sterilization of pathogenic substances in S2/S3 laboratories, with inline condensate sterilization.
Touch display (SteriTouch control) – enables simple and intuitive operation at the autoclave. In combination with user-friendly software, the autoclave can be operated quickly but also highly variable and simple.
Steam-air mixture method – for the sterilization of tightly closed bottles and pressure-sensitive materials. An additional temperature sensor, air deflectors and a circulating air fan ensure precise temperature control and distribution.
Rapid water recooling system with air-circulating fan – allows a shortening of the recooling time by more than 80% compared to the self cooling during sterilization of liquids. This is due to an internal heat exchanger, also known as a “fast cooler”, through which water flows.
Accessories – We offer stainless steel sterilization baskets, pails and containers which fit our various chamber designs.
Continue to the Laboratory-standing-autoclaves with up to 1.200 liters chamber volume.